Software raid is a type of raid implementation that utilizes operating systembased capabilities to construct and deliver raid services. Unfortunately, this software doesnt come with most distributions by default. The linux kernel contains an md driver that allows the raid solution to be completely hardware independent. But with budget favoring the software raid, those wanting optimum performance and efficiency of raid will have to go with the hardware raid. May 24, 2005 scott lowe responds to a techrepublic discussion and one members raid dilemma. Raid stands for redundant array of inexpensive disks. We just need to remember that the smallest of the hdds or partitions dictates the arrays capacity.
My experience with hardware and fake hardware raid is that as long as you stay with the same vendor, the raid metadata will be recognized ive seen this when moving drives between various hp, areca and lsi hardware raid controllers, and with intel, amd and even via hostraid i was pretty surprised when i connected a 250gb hard drive from some old amd desktop box to a hp g1 microserver, and. Whether software raid vs hardware raid is the one for you depends on what you need to do and how much you want to pay. Hotswap support is spotty not all software raid implementations support hot swapping. Flexibility is the key advantage of an open source software raid, like linux mdadm, but may require a specialized skillset for proper. But the real question is whether you should use a hardware raid solution or a software raid solution. Benefits and drawbacks of hybrid, hardwareassisted software raid. Someone told me that linux s software raid was less reliable than hardware raid. Jul 07, 2009 a redundant array of inexpensive disks raid allows high levels of storage reliability. You have to firstly tell your system to stop using the disk and then replace the disk. On the software side, todays software raid is superfast at least with linux and bsd, extremely flexible, and highly integrated into oss.
It combines multiple inexpensive, small disk drives into an array of disks in order to provide redundancy, lower latency maximizing the chanc. Windows software raid vs hardware raid 10 posts arlesterc. Additionally, hardwareassisted software raid usually comes with a variety of drivers for the most popular operating systems, and therefore, is more os independent than pure software raid. How to create a software raid 5 in linux mint ubuntu.
The hardwarebased array manages the raid subsystem independently from the. Lets start the hardware vs software raid battle with the hardware side. It is going to be for low performance file serving so performance is not a big issue, only reliability. May, 2011 a redundant array of inexpensive disks raid allows high levels of storage reliability. Hardware raid and implications for the future duration. With todays faster cpus, software raid outperforms hardware raid. It sounds like you configured the raid via the bios though so definitely use that. The basic idea of raid redundant arrays of inexpensive disks is to combine multiple small, independent disk drives into an array of disk drives which yields performance and recoverability exceeding that of a single large expensive drive sled.
Jun 03, 2017 software raid is a newer type of raid and its cheaper than hardware raid,where no specialized hardware is needed, and the host computer is responsible for the drives. Windows software raid vs hardware raid ars technica. Jul 06, 2011 reasons for using software raid versus a hardware raid setup. Replacing failed disk in the software raid is a bit more complex. Software raid is a newer type of raid and its cheaper than hardware raid,where no specialized hardware is needed, and the host computer is responsible for the drives. Software raid is generally slower and less reliable than a hardware solution. A brief history of raid raid has been around since 1970s 1989 berkeley paper was a taxonomy 1989 witnessed the first raid5 in software 1990s saw many hardware raid3, 5s lsi, 3ware, maxstrat, highpoint, intel 1990s also saw the introduction of raidframe mdraid came along in 2001. Dec 25, 2006 software raid is generally slower and less reliable than a hardware solution. For this purpose, the storage media used for this hard disks, ssds and so forth are simply connected to the computer as individual drives, somewhat like the direct sata ports on the motherboard. I think in hardware raid, if the hardware fails on the raid, you need the exact copy of the hardware to recover the data, i think. Plus, software raid permits users to reconfigure your arrays without being restricted by the hardware raid controller. With software raid your data can be split across different enclosures for complete redundancy one can completely stop working and your data is still ok. It can either be performed in the host servers cpu software raid, or in an external cpu hardware raid.
Software raid, as you might already know, is usually builtin on your os and unlike a hardware raid, you will need to spend a little extra on a controller card. But with budget favoring the software raid, those wanting optimum performance and. Feb 28, 2018 raid redundant array of independent disks is one of the popular data storage virtualization technology. Choosing between software raid and hardware raid depends on what you need to do and cost. Hardware raid is handled by a specialized raid controller card which does its own processing to make many devices act like one. Its also much more capable and powerful in recovery situations than hardware raid. Hardware raid will cost more, but it will also be free of software raid s. How to set up a software raid on linux addictivetips. What is the difference between hardware raid and software. My own tests of the two alternatives yielded some interesting results. Additionally, hardware assisted software raid usually comes with a variety of drivers for the most popular operating systems, and therefore, is more os independent than pure software raid. Under software raid, that configuration is performed in the.
I have a zfs raid 10 software raid as my primary storage setup and the read speeds i get are more than enough to saturate my gigabit ethernet. This is because it needs to process the data before it is written to disk. For software raid i used the linux kernel software raid functionality of a system running 64bit fedora 9. Ive actually had up to 3 hd movies streaming off the array simultaneously with no issues and not even putting a dent in what the setup can do. Your best bet for raid on linux is either to stick with the software raid which works ok or to move to an enterprise grade server with an integrated raid controller and supported disks. You can benchmark the performance difference between running a raid using the linux kernel software raid and a hardware raid card. Comparison of software raid on windows versus linux. Software raid virtually belongs to operating system. Software raid also works with cheaper ide disks as well as scsi disks. All of todays operating systems have some form of software raid built into them os x, windows 710 and linux. Windows home server v1s drive extender was not a raid 1 implementation, but it utilize the cpu to make stored data. The drives are configured, so that the data is either divided between disks to distribute load, or duplicated to ensure that it can be recovered once a disk fails. The raid implementation in winxp in my opinion is flawed to the point of making it unusable.
Here are some tips on raid levels and some feedback on the software vs. Imho, im a big fan of kernel developers non directly related to zfs, so i really prefere mdadm to hardware raid. My experience with hardware and fakehardware raid is that as long as you stay with the same vendor, the raid metadata will be recognized ive seen this when moving drives between various hp, areca and lsi hardware raid controllers, and with intel, amd and even via hostraid i was pretty surprised when i connected a 250gb hard drive from some old amd desktop box to a hp g1 microserver, and. Benefits and drawbacks of hybrid, hardware assisted software raid. Linux software raid often called mdraid or mdraid makes the use of raid possible without a hardware raid controller. Dell makes some remarkably cheap hardware with built in controllers.
We can use full disks, or we can use same sized partitions on different sized drives. Differences between hardware raid, hbas, and software raid. Lowend hardware raid vs software raid server fault. In a hardware raid setup, the drives connect to a raid controller card inserted in a fast pciexpress pcie slot in a motherboard. Someone told me that linuxs software raid was less reliable than hardware raid. If you configured the raid via software raid mdadm the use that. With cheaper hardware raid you can also lose data if theres a power outage. Dec 01, 2014 what they dont agree on is whether software raid can replace hardware raid in many applications that need access to large volumes of digital data and content quickly. That is what the thread was about, mainly, will raid 1 benefit enough to justify the extra risk and investment for a hw controller. Comparing hardware raid vs software raid setups deals with how the storage drives in a raid array connect to the motherboard in a server or pc, and the management of those drives. Before raid was raid, software disk mirroring raid 1 was a huge profit generator for system vendors, who sold it as an addon to their operating systems.
A redundant array of inexpensive disks raid allows high levels of storage reliability. Mdadm is a commandline utility that allows for quick and easy manipulation of raid devices. In a hardware raid setup, the drives connect to a special raid controller inserted in a fast pciexpress pcie slot in a motherboard. What they dont agree on is whether software raid can replace hardware raid in many applications that need access to large volumes of digital data and content quickly.
The performance of a softwarebased array depends on the server cpu performance and load. Which is why i went with linux software raid1 in the old system using an sil3114r pci controller card with a intel 440bx chipset. Numerous server oses support raid configuration, including those from apple, microsoft, various linux flavours as well as openbsd, freebsd. A raid can be deployed using both software and hardware. Aug 14, 2018 replacing failed disk in the software raid is a bit more complex. The best way to create a raid array on linux is to use the mdadm tool. We list the pros and cons of hardware vs software raid to help you decide. Hardware raid will cost more, but it will also be free of software raids. Software vs hardware raid performance and cache usage server. This card is either configured through bios extensionsyou may get an extra hit esc to setup message on boot or through proprietary utilities. Apr 05, 2019 on the software side, todays software raid is superfast at least with linux and bsd, extremely flexible, and highly integrated into oss. Common incarnations of software raid would include the oracle sun zfs, linuxs mdadm, flexraid, drobo beyondraid, lime technologys unraid, windows dynamic disk basedraid functionality, netapps raiddp, and etc. What is the difference between a software and hardware raid. Difference between hardware raid and software raid.
Scott lowe responds to a techrepublic discussion and one members raid dilemma. Sep 30, 2018 with this program, users can create a software raid array in a matter of minutes. Bsd opensolaris and linux raid software drivers are open source. It is used to improve disk io performance and reliability of your server or workstation. With this program, users can create a software raid array in a matter of minutes. This table summarizes the key differences between hardware and software raids. Ive been hoping other people would post with some experience, because im in the middle of a decision and am leaning toward software but just basically fear the unknown. Configuration is still required, but that configuration takes place outside the system.
I am trying to build a raid array only for reliability. Unlike hardware raid, software raid uses the processing power of the operating system in which the raid disks are installed. Raid redundant array of independent disks is one of the popular data storage virtualization technology. Software vs hardware raid nixcraft nixcraft linux tips. Soft possibly the longest running battle in raid circles is which is faster, hardware raid or software raid. Jun, 2016 comparing hardware raid vs software raid setups deals with how the storage drives in a raid array connect to the motherboard in a server or pc, and the management of those drives. I think in hardware raid, if the hardware fails on the raid, you need the exact copy of the hardware to recover the data, i. In testing both software and hardware raid performance i employed six 750gb samsung sata drives in three raid configurations 5, 6. This is a method of improving the performance and reliability of your storage media by using multiple drives. Software raid can have trouble with dissimilar drives. Hardware raid presents logical disks that are already configured to the system or the san, mirrored and ready to go. I wasnt sure if this one, being designed specifically for servers, would have true hardware raid and not fakeraid like the pci card.
1073 1565 326 957 670 1393 1306 227 409 1417 8 1003 1561 347 673 856 1348 1136 774 595 1113 1293 1086 1327 722 1490 865 509 666 1199 842 1389 474 644 380